E-ISSN 2548-0839
Volume : 9 Issue : 2 Year : 2024

Metrics

1.8
2022 IMPACT FACTOR
1.6
5 year Impact Factor
0.00041
Eigenfactor
2.6
2022 CiteScore
90/157
Journal Citation Reports (Clarivate, 2023)(Dentistry, Oral Surgery & Medicine (Science))
SCImago Journal & Country Rank
Micro-Computed Tomographic Analysis of the Shaping Ability of XP-Endo Shaper in Oval-Shaped Distal Root Canals of Mandibular Molars [Eur Endod J]
Eur Endod J. 2021; 6(3): 271-277 | DOI: 10.14744/eej.2021.44153

Micro-Computed Tomographic Analysis of the Shaping Ability of XP-Endo Shaper in Oval-Shaped Distal Root Canals of Mandibular Molars

Ane Poly1, Wei-Ju Louis Tseng2, Fernando Marques3, Frank Carsten Setzer3, Bekir Karabucak3
1Department of Integrated Clinical Procedures, School of Dentistry, Rio de Janeiro State University, Rio de Janeiro, Brazil
2Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA;Department of Medicine, Center for Translational Medicine, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
3Department of Endodontics, School of Dental Medicine, University of Pennsylvania, Philadelphia, USA

Objective: To compare the shaping ability of the XP-endo Shaper (XPS) system to the ProTaper Next (PTN) system in oval-shaped distal root canals.
Methods: From 12 mandibular molars, distal roots with moderately curved single oval canals were randomly assorted to be instrumented with XPS (experimental group) or PTN (control group) and then scanned using micro-computed tomography [Scan 1]. The root canals of the XPS samples were prepared following the manufacturer's instructions using 15 insertions (XPS15) and rescanned [Scan 2]. An additional 10 insertions to the working length were applied, totalling 25 insertions (XPS25), and the roots were rescanned again [Scan 3]. PTN samples were prepared up to the X3 instrument (PTNX3) and rescanned [Scan 2]. The dentine removed and the unprepared areas were assessed. Data were analysed using a t-test with significance at α=0.05.
Results: XPS25 was associated with a significantly greater dentine removal than XPS15 over the entire root canal length and in all three-thirds of the root canal (P<0.05). XPS25 significantly removed more dentine than PTNX3 in only the coronal third (P<0.05). XPS25 was also associated with a significantly smaller percentage of unprepared areas than XPS15 overall and in the coronal third (P<0.05). PTNX3 was associated with a significantly larger percentage of unprepared areas than XPS15 and XPS25 overall and in the coronal and middle
thirds (P<0.05).
Conclusion: Ten additional movements with XPS significantly improved instrumentation capacity, reducing the percentage of untouched surface areas but also removing more dentine. (EEJ-2021-01-017)

Keywords: Dental instruments, endodontics, root canal preparation, X-Ray microtomography

Ane Poly, Wei-Ju Louis Tseng, Fernando Marques, Frank Carsten Setzer, Bekir Karabucak. Micro-Computed Tomographic Analysis of the Shaping Ability of XP-Endo Shaper in Oval-Shaped Distal Root Canals of Mandibular Molars. Eur Endod J. 2021; 6(3): 271-277

Corresponding Author: Frank Carsten Setzer
Manuscript Language: English
LookUs & Online Makale